蒸汽发生器二次侧打压试验水温控制与水质调节  被引量:2

The Temperature Control and Water Quality Regulation for Steam Generator Secondary Side Hydrostatic Test

在线阅读下载全文

作  者:肖波 刘东勇 

机构地区:[1]福建福清核电有限公司,福建福清350318 [2]中国核电工程有限公司,北京100048

出  处:《中国核电》2014年第3期250-255,共6页China Nuclear Power

摘  要:M310型机组蒸汽发生器二次侧水压试验,是对蒸汽发生器二次侧管板的严密性及相关系统耐压性的验证。由于蒸汽发生器的重要性,其水压试验用水对温度及水质有着严格的要求。通过对福清核电1号机组二回路水压试验水温控制和水质调节的探讨,有助于对M310型机组蒸汽发生器水压试验准备工作起到良好的指导意义。The secondary side hydrostatic test for the steam generator of M310 unit is to verify the pressure tightness of steam generator secondary side tube sheet and related systems. As for the importance of the steam generator, the water temperature and water quality of hydrostatic test has strict requirements. The discussion on the water temperature control and water quality regulation for the secondary loop hydrostatic test of Fuqing Unit 1 contribute greatly to the guiding work for the preparation of the steam generator pressure test for M310 unit.

关 键 词:蒸汽发生器 水压试验 水温控制 水质调节 

分 类 号:TM623[电气工程—电力系统及自动化]

 