检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张廷鹏
机构地区:[1]上海纬纵化工工程咨询有限公司,暖通部门,上海200235
出 处:《广东化工》2014年第19期169-170,172,共3页Guangdong Chemical Industry
摘 要:生产车间采用一次回风的全空气中央空调系统,房间的正压由新风量控制,以达到室内10~15 Pa的正压值,新风单独处理,和回风混合后再经直接蒸发盘管处理后送到室内;考虑本项目生产过程中会产生纤维粉尘,因此生产车间空调系统的空调箱过滤段采用了多筒式滤尘器,自动过滤和收集经空气中的纤维粉尘,避免了频繁清洗、更换空调过滤器带来的不便.Primary return air handling unit system is adopted for Workshop, the room overpressure is controlled by the fresh air volume, to fit the10-15 Pa overpressure value, fresh air is handled independently, it is mixed with indoor air, mixture air is handled by direct-expansion coil, and it is transported to room; in consideration of fibrous dust is produced in the process, so Multi drum filter unit is used as medium efficiency filter in the AHU for workshop, fibrous dust is fltrated and collected by Multi drum filter unit, avoiding to wash and exchange the filter frequently.
关 键 词:一次回风中央空调系统 新风单独处理 多筒式滤尘器 纤维粉尘
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.222.132.108