检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]同济大学机械与能源工程学院,上海201804 [2]同济大学上海地面交通工具风洞中心,上海201804
出 处:《发电与空调》2014年第5期67-71,共5页
摘 要:针对应用于电站直接空冷凝汽器的蛇形翅片扁平单排管,对其空气侧的流动及换热特性进行了数值模拟。给出了该管件基本结构的雷诺数和欧拉数随迎面风速的变化关联式;结果显示,同一迎面风速下,随着翅片间距、高度的增大,换热变差,流动变好。但当间距增加到一定程度时,风速与间距对换热流动性能的影响都变得很小。风速越大,换热性能对翅片间距、高度越敏感,而流动则相反,需根据实际工况来选择合适的翅片间距及高度。The air-side flow and heat transfer characteristic of single row wave-finned flat tube which is applied in direct air-cooling condensers in power station are investigated numerically. And the results show that the bigger velocity, the better heat transfer performance and the worse flow performance. As the fin pitch and height go larger at the same velocity, heat transfer coefficient of the air-side and flow friction go smaller. But the air velocity and the fin pitch can barely influence flow and heat transfer performance when the pitch is too big. The fin pitch and height should be determined according to working conditions.
分 类 号:TM621[电气工程—电力系统及自动化]