检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]昆明理工大学冶金与能源工程学院,云南昆明650093 [2]重庆大唐国际石柱发电有限责任公司,重庆409106
出 处:《热力发电》2014年第10期100-102,115,共4页Thermal Power Generation
摘 要:锅炉过热蒸汽温度过高或过低都会影响电厂的安全性和经济性,且过热蒸汽温度的控制具有大迟延、扰动因素多、控制精度和稳定性要求高的特点。针对某亚临界2×600MW机组实际运行参数及其锅炉低氮燃烧改造后的过热蒸汽温度特性,对过热蒸汽温度控制策略进行了优化。优化后在机组调峰频繁工况下,控制系统将过热蒸汽温度波动范围控制在±4.5℃以内,控制系统调节品质明显提高。Overhigh or overlow superheated steam temperature in boiler will significantly affect safety and e-conomy of power plants.The superheated steam temperature control system has such characteristics as large delay,multiple disturbance factors and high requirements for control precision and stability.On the basis of the actual operation parameters and superheated steam temperature characteristics of a sub-critica1 600 MW unit boiler after low NOx combustion transformation,the superheated steam temperature control strategy was optimized.The improved control system can regulate the superheated steam temperature fluc-tuation within ±4.5 ℃,indicating the control quality of the system has been dramatically enhanced.
分 类 号:TK22[动力工程及工程热物理—动力机械及工程] TK323