摘 要:介绍一种全新的平板式太阳集热器,该集热器应用微热管阵列作为集热元件,具有成本低、抗冻、承压、不易结垢、易与建筑一体化等优点。对其瞬时热性能进行的实验研究表明,该集热器瞬时效率曲线的截距达83.1%,斜率为-4.77。建立了微热管阵列平板太阳集热器的CFD模型,对集热器内部流体流动与换热进行数值模拟,模拟结果与实验结果吻合较好,从而验证了模型的可靠性。采用CFD模型对集热器干式接触式换热器进行优化,结果表明,该集热器循环水的最佳流量为0.1-0.2kg/(m2·S),水流量较低时,采用直内肋管可适当提高集热效率,随着流量的增加,管内加肋对集热器性能的提高影响不大。In this study, a novel flat plate solar collector with micro heat pipe array was proposed. One such flat plate solar collector shows many advantages, such as: much cheaper, absence of freezing, high pressure resistance, easy integration into buildings etc. A thermal performance experimental study was conducted, focusing on the collector efficiency. The results showed that the collector's maximum instantaneous efficiency is up to 83.1% and the total heat loss factor is 4.77. A CFD model was developed to analyze the fluid flow and heat transfer within the collector, the instantaneous efficiency was compared with experimental resuhs and there is a good agreement. Optimal study Was conducted for the heat exchanger with dry type by CFD simulation, and the results showed that the optimal mass flow rate is 0.1-0.2 kg/(m2-s), and the heat exchanger with fins has better efficiency at low mass flow rate than without fins.
关 键 词:微热管阵列 新型平板太阳集热器 CFD模拟 干式接触式换热器 质量流量
分 类 号:TK519[动力工程及工程热物理—热能工程]