检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]华北电力大学电气与电子工程学院,河北保定071003
出 处:《计量学报》2014年第6期545-549,共5页Acta Metrologica Sinica
摘 要:直流偏磁与剩磁的存在会改变测量用电流互感器在铁心磁化曲线上的工作点,直接影响电能计量与测量的准确性。提出了一种基于三参数正弦曲线拟合算法的比差、角差测量方法,并通过实验分析了直流偏磁与剩磁对测量用电流互感器误差特性的影响。实验数据表明,直流偏磁与剩磁都会使比差和角差向着不同的方向增大,而且当直流偏磁与剩磁同方向同时存在时误差将会远远超过规定的限值,从而导致电能计量与测量的结果出现较大偏差。DC bias and remnant flux will change the measuring current transformer working point in the core magnetization curve and have a direct impact on the accuracy of electric energy measurement. An error measurement method based on the algorithm for three-parameter least squares fit to sine wave is put forward and the influence of DC bias and remnant flux on error characteristics of current transformer is also investigated throUgh experiments. The experimental data shows that DC bias and remnant flux will increase the ratio error and phase displacement in opposite directions and the ratio and phase displacement will be far more than the limit value when they are exist in same direction at the same time. This will seriously affect the transmission accuracv of current transformer.
关 键 词:计量学 测量用电流互感器 直流偏磁 剩磁 比差 角差
分 类 号:TB972[一般工业技术—计量学]