夏热冬冷地区公共建筑空调排风热回收的节能分析  被引量:1

Energy Saving Analysis of Public Building Air Conditioning Room' Exhaust Heat Recovery in Hot Summer and Cold Winter Area

在线阅读下载全文

作  者:张新桥[1] 

机构地区:[1]湖南城市学院市政与测绘工程学院,湖南益阳413000

出  处:《湖南城市学院学报(自然科学版)》2014年第3期10-13,共4页Journal of Hunan City University:Natural Science

基  金:湖南省教育厅科技计划资助项目(11C0255)

摘  要:以夏热冬冷地区3个典型建筑为例,分析了3类典型建筑的总冷(热)负荷、新风冷(热)负荷分布情况,计算了采用排风热回收装置处理新风后降低的负荷量,并对采用新风换气装置后的投资进行了经济性分析.采用新风换气装置后总投资变化不大,但运行费用却能大大降低.In this paper, taking three typical buildings in hot summer and cold winter area as an example, the author analyzes the distribution of the three kinds of typical building total cold (heat) load and the fresh air cool (heat) load, calculates the load reduce after the fresh air treated by the exhaust heat recovery unit and analyzes the economic efficiency of the fresh air exchange device. Little change in the total investment by the fresh air exchange device, but it can reduce the operation cost.

关 键 词:空调负荷 排风 新风 节能 

分 类 号:TU831[建筑科学—供热、供燃气、通风及空调工程]

 