作 者:吴芳芳 周泽然 杨永良 孙葆根 邹俊颖 卢平 程超才 罗箐 徐君
出 处:《Nuclear Science and Techniques》2014年第5期6-9,共4页核技术(英文)
基 金:Supported by the Natural Science Foundation of China(Nos.11175173,11375178 and 11005105)
摘 要:The four electrodes in the stripline beam position monitor(BPM) for Hefei Light Source(HLS II) storage ring are of axially symmetric type. We have derived a new calibration method of electrode gains for this type stripline BPM. The gain fit error of different data grids was analyzed, and the ±5 mm by ±5 mm grid is the best.The electrode gains of two stripline BPMs(HLS II SR-BD-STLB1 and HLS II SR-BD-STLB2) were obtained based on offline calibrated data. The results show that data after fitting gains are improved, with the electrode gains being between 0.94 and 1.15.The four electrodes in the stripline beam position monitor (BPM) for Hefei Light Source (HLS II) storage ring are of axially symmetric type. We have derived a new calibration method of electrode gains for this type stripline BPM. The gain fit error of different data grids was analyzed, and the ±5 mm by ±5 mm grid is the best. The electrode gains of two stripline BPMs (HLS II SR-BD-STLB 1 and HLS II SR-BD-STLB2) were obtained based on offline calibrated data. The results show that data after fitting gains are improved, with the electrode gains being between 0.94 and 1.15.
关 键 词:条形电极 轴向对称 校准方法 BPM 带状线 增益 数据网格 HLS
分 类 号:TL594[核科学技术—核技术及应用]