用HPLC测定羟基苯乙酸-N,N-二甲氨基甲酰甲酯含量的研究  被引量:1

Research on the determination methods of N,N-dimethylcarbamoylmethyl-p-hydroxyphenylacetate

在线阅读下载全文

作  者:李宗霖[1] 麻纪斌 曲秦 翟帆[1] 舒泉湧 秦湫红 

机构地区:[1]陕西新药技术开发中心,陕西西安710075

出  处:《应用化工》2014年第10期1922-1924,共3页Applied Chemical Industry

摘  要:以高效液相色谱法(HPLC)测定对羟基苯乙酸-N,N-二甲氨基甲酰甲酯的含量,采用Thermo Syneronis C18柱(250mm×4.6mm,5μm),以乙腈-水=30:70(V/V)为流动相,流速1.0mL/min,检测波长275nm。结果表明,对羟基苯乙酸-N,N-二甲氨基甲酰甲酯在0.1-1.0μg范围内线性关系良好,加样回收率为98.8%,RSD=1.08%。该方法准确,便捷,重现性好,适用于对羟基苯乙酸-N,N-二甲氨基甲酰甲酯的含量测定及工业生产中的质量控制。Determination of N,N-dimethylearbamoylmethyl-p-hydroxyphenylaeetate by HPLC. The analyti-eal eolumn was Thermo Syneronis C18(250 mm ×4. 6 mm,5μm). The mobile phase eonsisted of aeetoni-trile-water(30:70). The flow rate was 1. 0 mL/min and the deteetion wavelength was 275 nm. Results showed that the linear range of N,N-dimethylearbamoylmethyl-p-hydroxyphenylaeetate was at 0. 1 -1. 0 μg,and the average reeovery was 98. 8%,RSD was 1. 08%. The method is aeeurate,eonvenient, good reprodueibility and ean be used for the eontent determination of N,N-dimethylearbamoylmethyl-p-hydroxyphenylaeetate. Also suitable for the quality eontrolling during the industrial produeing process.

关 键 词:对羟基苯乙酸-N N-二甲氨基甲酰甲酯 高效液相色谱法 含量测定 

分 类 号:TQ063[化学工程] R927.2[医药卫生—药学]

 