A new measurement method for electrode gain in an orthogonally symmetric beam position monitor  

A new measurement method for electrode gain in an orthogonally symmetric beam position monitor

在线阅读下载全文

作  者:邹俊颖 吴芳芳 杨永良 孙葆根 周泽然 罗箐 卢平 徐宏亮 

机构地区:[1]NSRL,School of Nuclear Science and Technology University of Science and Technology of China

出  处:《Chinese Physics C》2014年第12期59-63,共5页中国物理C(英文版)

基  金:Supported by National Natural Science Foundation of China(11175173,11375178,11105141)

摘  要:The new beam position monitor(BPM) system of the injector at the upgrade project of the Hefei Light Source(HLS II) has 19 stripline beam position monitors. Most consist of four orthogonally symmetric stripline electrodes. Differences in electronic gain and mismachining tolerance can cause changes in the beam response of the BPM electrodes. This variation will couple the two measured horizontal positions, resulting in measuring error. To alleviate this effect, a new technique to measure the relative response of the four electrodes has been developed. It is independent of the beam charge, and the related coefficient can be calculated theoretically. The effect of electrode coupling on this technique is analyzed. The calibration data is used to fit the gain for all 19 injector beam position monitors. The results show the standard deviation of the distribution of measured gains is about 5%.The new beam position monitor(BPM) system of the injector at the upgrade project of the Hefei Light Source(HLS II) has 19 stripline beam position monitors. Most consist of four orthogonally symmetric stripline electrodes. Differences in electronic gain and mismachining tolerance can cause changes in the beam response of the BPM electrodes. This variation will couple the two measured horizontal positions, resulting in measuring error. To alleviate this effect, a new technique to measure the relative response of the four electrodes has been developed. It is independent of the beam charge, and the related coefficient can be calculated theoretically. The effect of electrode coupling on this technique is analyzed. The calibration data is used to fit the gain for all 19 injector beam position monitors. The results show the standard deviation of the distribution of measured gains is about 5%.

关 键 词:beam position monitor electrode gain CALIBRATION orthogonal symmetric 

分 类 号:TL506[核科学技术—核技术及应用]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象