检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]中核272铀业有限责任公司,湖南衡阳421004
出 处:《铀矿冶》2014年第4期223-226,共4页Uranium Mining and Metallurgy
摘 要:采用TBP萃淋树脂,在酸性介质中使铀与待测元素定量分离,用ICP-AES法同时测定二氧化铀中钾、钠的含量.当试样平行测定6次时,钾、钠测定结果相对标准偏差分别为5.8%和6.4%,加标回收率分别为93.5%~104.3%和92.3%~102.8%.称样质量为0.5g时,方法的测定下限钾、钠分别为0.11×10-6和0.07×10-6.该方法满足二氧化铀中痕量钾、钠的分析要求.In acid medium uranium is separated from impurities by TBP Eluex resin, and potassium and sodium in uranium dioxide were determined simultaneously by ICP-AES method. When the sam- ple is measured 6 times in parallel, the measurement result of relative standard deviations is 5.8 % for potassium, and 6.4% for sodium as well as recovery is 93.5% -107.0% for potassium, and 91.5- 102.8% for sodium. If sample mass is 0.5 g, and 0.07 × 10-6 for sodium respectively. The potassium and sodium in uranium dioxide. lower limit of the method is 0.11 × 10-6 for potassium method can meet requirements of determination of trace
关 键 词:二氧化铀 钾 钠 ICP-AES TBP萃淋树脂
分 类 号:TL271.4[核科学技术—核燃料循环与材料]