Parylene涂层封堵器治疗儿童先天性心脏病疗效观察  被引量:13

Efficacy of Parylene coating occluder in the treatment of children with congenial heart disease

在线阅读下载全文

作  者:秦莉[1] 易岂建[1] 李谧[1] 吕铁伟[1] 白永红[1] 计晓娟[1] 蒲晓芳[1] 罗雪[1] 

机构地区:[1]重庆医科大学附属儿童医院心内科,儿童发育疾病研究教育部重点实验室,儿科学重庆市实验室,重庆市儿童发育重大疾病诊治与预防国际科技合作基地,重庆400014

出  处:《重庆医科大学学报》2014年第10期1403-1409,共7页Journal of Chongqing Medical University

基  金:重庆市卫生局资助(编号:2012-2-084)

摘  要:目的:探讨Parylene涂层封堵器(Parylene coating occluder)治疗儿童先天性心脏病(congenial heart diseases,CHD)的临床安全性、有效性及阻断镍离子释放入血的效果。方法:将待实施介入治疗的CHD患儿23例按照随机分组原则分为派瑞林组(A组)及传统组(B组),均为北京华医圣杰医疗器械公司产品。A组12例,其中室间隔缺损(ventricular septal defects,VSD)4例,动脉导管未闭(patent ductus arteriosus,PDA)8例,B组11例,其中VSD 3例,PPA 8例。所有患儿均由其监护人签署知情同意书。2组均在X线、心脏彩超及心电图监测下完成经导管介入封堵治疗,于术前,术后1 d、1月、3月、6月随访观察临床症状体征、肝肾功、血常规、心电图、心脏彩超、胸片及血镍浓度变化情况。结果:2组介入封堵治疗均成功,成功率均为100%(23/23);A组中有1例术后即刻有少量残余分流,随访至术后6月时残余分流消失。无机械性溶血、封堵器脱落、移位、心律失常等并发症发生。随访各时间点2组之间在临床症状体征、肝肾功能(分别为P=0.819、P=0.418、P=0.991、P=0.828)、血常规(分别为P=0.521、P=0.239、P=0.088)、心电图、心脏彩超(分别为P=0.249、P=0.239、P=0.213、P=0.071、P=0.397)、胸片(P分别为0.537、0.114)和血液镍离子浓度(P=0.797)方面均无统计学意义。结论:小儿CHD介入治疗中,Parylene涂层封堵器在有效性、安全性及阻断镍离子释放入血方面与传统封堵器无显著差异。Objective:To explore clinical safety and efficacy of Parylene coating occluder in the treatment of children with congenial heart diseases(CHD) and in the block of nickel release into blood. Methods :A total of 23 patients with CHD who would done tran- scatheter closure were divided into parylene goup(A group) and traditional group(B group). The devices of both group were supplied by Beijing Huayi Medical Equipment Company. There were 12 cases in A group,including 4 cases of ventricular septal defects(VSD) and 8 cases of patent ductus arteriosus(PDA) and there were 11 cases in B group,including 3 cases of VSD and 8 cases of PDA. All patients were informed consent form signed by his guardian. All cases in both groups completed percutaneous transcatheter closure therapy under X-ray,electrocardiography and transthoracic echocardiography, and were followed-up regarding clinical symptoms, hepatic and renal function, blood routine, echocardiography, electrocardiography, chest X-ray and nickel concentration before therapy, 1 d post therapy, 1 month post therapy, 3 months post therapy and 6 months post therapy respectively. Results : All treatments in both parylene group and tradional group were successful,with successful rate of 100%(23/23). Little residual shunt was observed in one case in parylene group just after the treatment but disappeared at 6 month after the treatment. No case had complications of mechani- cal hemolysis, devices shifting and falling off and arrhythmia. There was no significant difference between two groups in clinical symptoms and signs, hepatic and renal function (P=0.819, P=0.418, P=0.991, P=0.828), routine blood examination (P=0.521,P=0.239, P=0.088) ,echocardiography,transthoracic electrocardiography(P=0.249,P=0.239,P=0.213 ,P=0.071 ,P=0.397), chest X-ray(P=0.537 and P=0.114) and nickel concentration (P=0.797) at each follow-up time point. Conclusion :There is no significant difference between Parylene coating occluder and traditional occlud

关 键 词:封堵器 先天性心脏病 介入治疗 镍离子 儿童 

分 类 号:R725.4[医药卫生—儿科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象