在线固相萃取-液相色谱串联质谱法测定阿姆西汀异构体的药代动力学差异  被引量:1

Determination of Pharmacokinetics Differences of Ammuxetine Isomers in Rat Plasma Using On-Line Solid Phase Extraction with Liquid Chrommatography-Tandem Mass Spectrometry

在线阅读下载全文

作  者:李迎[1] 冯航[1] 龚伟[1] 喻芳邻[1] 谢向阳[1] 何新华[1] 张有志[1] 梅兴国[1] 

机构地区:[1]军事医学科学院毒物药物研究所,北京100850

出  处:《分析化学》2014年第12期1717-1722,共6页Chinese Journal of Analytical Chemistry

基  金:国家自然科学基金青年基金资助项目(No.81102498)~~

摘  要:建立了在线固相萃取-高效液相色谱-串联质谱法( On-line SPE HPLC-MS/MS)测定大鼠血浆中S/R-阿姆西汀手性异构体的方法。血浆样品经过以下预处理步骤:采用甲醇-乙腈(50:50, V/V)沉淀蛋白;应用On-line SPE将血浆样品中的其它杂质去除;将保留在SPE柱上的阿姆西汀和内标洗脱后用分析柱进一步分离。分离后再用串联质谱法分别测定大鼠血浆中S/R-阿姆西汀的含量。 SPE柱为 Retain PEP Javelin(10 mm ×2.1 mm);分析柱为ZORBAX SB-C18(50 mm ×2.1 mm×3.5μm)。质谱采用电喷雾离子源(ESI),多反应监测(MRM)模式,检测离子为正离子,分别选择m/z 292.1/154.0和260.4/116.2作为S/R-阿姆西汀和内标(普萘洛尔)的检测离子对。结果表明,S/R-阿姆西汀的线性范围为0.2~1000μg/L,相关系数 R 分别为0.9903和0.9951,批内精密度 RSD 分别为1.2%~12.0%和0.4%~11.2%,回收率分别为94.2%~101.6%和94.3%~109.4%之间。本方法显著提高了阿姆西汀的检测灵敏度,可以满足大鼠灌胃给予阿姆西汀两种异构体的药代动力学研究要求。An on-line solid phase extraction (SPE)coupled with HPLC-MS/MS method was developed to determine S-ammuxetine and R-ammuxetine in rat plasma. The sample preparation consisted of the following steps: A protein precipitation extraction used methanol and acetonitrile (50:50, V/V); an on-line SPE treatment to remove most matrixes in plasma; an enrichment and separation step used a Cls analytical column. S- and R-ammuxetine were determined by tandem mass spectrometry. The SPE column was a Retain PEP Javelin (10 mm×2.1 mm × 5μm) , while the chromatographic separation was achieved using a ZORBAX SB-C18 (50 mm x 2. 1 mmx 3.5 ~zm) analytical column with an isocratic mobile phase composed of acetonitrile-water-formic acid (40: 60: 0.1, V/V/V, 0.3 mL/min). The selected reaction monitoring mode of the positive ion was performed and the precursor to the product ion transitions of m/z 292. 1/154.0 and m/z 260.4/116.2 were used to measure S-ammuxetine, R-ammuxetine and internal standard (propranolol). The method was linear over a concentration range from 0.2 to 1000 μg/L with the correlation coefficients of 0.9903 and 0. 9951. The average intra-day precision values were 1.2% -12.0% for S-ammuxetine and 0.4%-11.2% for R-ammuxetine, respectively. The average recoveries were 94.2%-101.6% for S- ammuxetine and 94. 3%- 109.4% for R-ammuxetine. Compared to the literature, the sensitivity of this method increased dramatically. The present method has been successfully applied to the preclinical rat research of ammuxetine isomers following intragastric administration.

关 键 词:在线固相萃取-液相色谱质谱联用 阿姆西汀手性异构体 大鼠药代动力学 新型抗抑郁药 

分 类 号:R965[医药卫生—药理学] O657.63[医药卫生—药学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象