检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]中国水电顾问集团华东勘测设计研究院有限公司,浙江杭州310014
出 处:《人民长江》2014年第23期73-76,共4页Yangtze River
摘 要:针对江边水电站技术供水系统设备在汛期严重堵塞、影响机组安全稳定运行的问题,提出了循环冷却供水系统的改造方案。在改造过程中,结合电站实际情况,在仔细斟酌、就地取材的基础上,充分利用现有的设备和条件,降低工程造价,对系统实施优化。优化改造后,通过现场实测了解到,该系统运行良好,可靠性更高,且改善了机组水导轴瓦、发电机上导和下导以及发电机空冷器的温升,从而延长了设备的使用寿命,节约了检修维护费用。通过该工程案例的应用,说明循环冷却供水方案亦适合大中型地下厂房式水电站。The technical water supply system of Jiangbian Hydropower Station was often seriously blocked in the flood season, affecting safe and stable operation of the generating unit. Thus, a transformation scheme of circulating cooling water supply sys-tem was put forward. In the transformation process, the system was optimized and the cost was reduced by making full use of cur-rent facilities and considering the actual condition of the station. The field observation show the water system runs well and is more reliable since the transformation. The temperature rise of guide bearing bush and air cooler of generating units is improved greatly, thus prolonging service life of the equipment and reducing the cost of maintenance. It is demonstrated that the water sup-ply by circulating cooling water system is suitable for large underground hydropower stations.
分 类 号:TV731.6[水利工程—水利水电工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.26