国产600MW超临界机组冷端节能优化  

Cold-side Optimization of 600MW Supercritical Units

在线阅读下载全文

作  者:李大才 赵艳粉[2] 高峰 

机构地区:[1]广东大唐国际潮州发电有限责任公司,潮州515723 [2]上海材料研究所,上海200437

出  处:《电力与能源》2014年第6期749-751,787,共4页Power & Energy

摘  要:对潮州发电公司两台600 MW机组真空系统及设备进行改进,并通过试验表明了真空系统并联方式下的机组背压、运行经济性优于串联方式,双级真空泵的抽真空能力及节能效果明显优于单级真空泵,新式二次滤网具有较高的安全性和经济性。通过真空查漏找到了机组的明显漏点,提高了机组的严密性,真空系统及设备改造和优化对机组的经济性影响明显。Chaozhou power company for the vacuum system of 600 MW two units and equipment was improved,and the results showed that the unit back pressure,economically superior to run parallel vacuum system under the series,double stage vacuum pump capacity and obvious energy saving effect was better than the single stage vacuum pump,safety and economy of the new two screen with higher,by vacuum leak leak unit was found out,improved the tightness of the unit,vacuum system and equipment modification and optimization of the economic impact on the unit obviously.

关 键 词:冷端 凝汽器 真空系统 真空泵 二次滤网 真空查漏 

分 类 号:TP29[自动化与计算机技术—检测技术与自动化装置]

 