检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:刘希禹[1]
机构地区:[1]中讯邮电咨询设计院有限公司,河南郑州450007
出 处:《UPS应用》2014年第12期25-30,共6页UPS Applications
摘 要:国际电信联盟(ITU)标准ITU-TL.1200规定了在电信和数据通信(ICT)设备输入端高达400V的直流供电接口及其正常电压范围(260~4-00VDC)。我国当前研究试验和推广应用的240V高压直流供电系统的正常电压范围(192~288V%)偏低偏窄,或应在有限的时间内过渡到ITU建议的目标电压范围。文中介绍ITU对高达400VDC的直流供电接口的要求、供电系统结构、接地系统设计考虑和ICT设备抗干扰试验要求。International telecommunication union (ITU) standard of ITU-TL.1200 specifies direct current power feeding interface ofup to 400V at the input to telecommunication and datacom (ICT) equipment. It also describes the normal voltage range (260-400VDC).The normal voltage range (192-288VDC) of 240V high voltage direct current power feeding system which is being developed and used in China is relatively lower and narrower. It should probably beevolved toward the target voltage range recommended by ITU in limited time. This paper describes ITU specifications ofdirect current power feeding interfaceup to 400V, the constructionsof power feeding systems, thedesign considerations of grounding system and therequirementsof immunity test for ICT equipment.
关 键 词:高压直流 电信和数据通信OCT)设备 正常电压范围 接口P
分 类 号:TM721.1[电气工程—电力系统及自动化]