电信和数据通信设备高压直流供电系统的发展目标(下)——高达400V的直流供电系统  

Development Target of High Voltage Power Feeding System for Telecom and Datacom(ICT) Equipment--aPower Feeding System of up to 400VDC

在线阅读下载全文

作  者:刘希禹[1] 

机构地区:[1]中讯邮电咨询设计院有限公司,河南郑州450007

出  处:《UPS应用》2014年第12期25-30,共6页UPS Applications

摘  要:国际电信联盟(ITU)标准ITU-TL.1200规定了在电信和数据通信(ICT)设备输入端高达400V的直流供电接口及其正常电压范围(260~4-00VDC)。我国当前研究试验和推广应用的240V高压直流供电系统的正常电压范围(192~288V%)偏低偏窄,或应在有限的时间内过渡到ITU建议的目标电压范围。文中介绍ITU对高达400VDC的直流供电接口的要求、供电系统结构、接地系统设计考虑和ICT设备抗干扰试验要求。International telecommunication union (ITU) standard of ITU-TL.1200 specifies direct current power feeding interface ofup to 400V at the input to telecommunication and datacom (ICT) equipment. It also describes the normal voltage range (260-400VDC).The normal voltage range (192-288VDC) of 240V high voltage direct current power feeding system which is being developed and used in China is relatively lower and narrower. It should probably beevolved toward the target voltage range recommended by ITU in limited time. This paper describes ITU specifications ofdirect current power feeding interfaceup to 400V, the constructionsof power feeding systems, thedesign considerations of grounding system and therequirementsof immunity test for ICT equipment.

关 键 词:高压直流 电信和数据通信OCT)设备 正常电压范围 接口P 

分 类 号:TM721.1[电气工程—电力系统及自动化]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象