A Fiber Optic Sensor for 2-cholrophenol Analysis based on Oxygen Sensing System  

A Fiber Optic Sensor for 2-cholrophenol Analysis based on Oxygen Sensing System

在线阅读下载全文

作  者:贡晶晶 HUANG Xinting HUANG Jun DING Liyun LI Kun YUAN Yinquan 

机构地区:[1]National Engineering Laboratory for Fiber Optic Sensing Technology, Wuhan University of Technology [2]Key Laboratory of Fiber Optic Sensing Technology and Information Processing (Wuhan University of Technology),Ministry of Education [3]Faculty of Mechanical & Electronic Information, China University of Geosciences

出  处:《Journal of Wuhan University of Technology(Materials Science)》2014年第6期1178-1182,共5页武汉理工大学学报(材料科学英文版)

基  金:Funded by the National Natural Science Foundation of China(No.61377092)

摘  要:A fiber optic 2-cholrophenol(2-CP) sensor was developed based on the fluorescence quenching of molecular oxygen on the oxygen-sensitive membrane and O2 consumption during catalytic oxidation reaction of 2-CP. The 2-CP concentration can be determined by utilizing a lock-in amplifier to measure the change in the fluorescence lifetime of an oxygen-sensitive membrane, in which the tris(2,2′-bipyridyl) ruthenium(II) chloride complexes(Ru(II)(byp)3Cl2) were immobilized in cellulose acetate(CA) via simple hybridized approach. The experimental results show the good linear relationship between the phase delay of sensitive membrane and 2-CP concentration in its detection range of 1×10-7 to 1×10-5 mol/L and 1×10-5 to 1×10-4 mol/L. The detection limit of the sensor is 7×10-8 mol/L(S/N=3) and the response time is 5 min. Our experimental measurements confirmed good response characteristics of the as-prepared fiber optic 2-CP sensor, as well as its capability to detect the 2-CP concentration in practical water samples.A fiber optic 2-cholrophenol(2-CP) sensor was developed based on the fluorescence quenching of molecular oxygen on the oxygen-sensitive membrane and O2 consumption during catalytic oxidation reaction of 2-CP. The 2-CP concentration can be determined by utilizing a lock-in amplifier to measure the change in the fluorescence lifetime of an oxygen-sensitive membrane, in which the tris(2,2′-bipyridyl) ruthenium(II) chloride complexes(Ru(II)(byp)3Cl2) were immobilized in cellulose acetate(CA) via simple hybridized approach. The experimental results show the good linear relationship between the phase delay of sensitive membrane and 2-CP concentration in its detection range of 1×10-7 to 1×10-5 mol/L and 1×10-5 to 1×10-4 mol/L. The detection limit of the sensor is 7×10-8 mol/L(S/N=3) and the response time is 5 min. Our experimental measurements confirmed good response characteristics of the as-prepared fiber optic 2-CP sensor, as well as its capability to detect the 2-CP concentration in practical water samples.

关 键 词:fiber optic sensor 2-chlorophenol oxygen-sensitive membrane fluorescence quenching 

分 类 号:TP212[自动化与计算机技术—检测技术与自动化装置] TQ426.81[自动化与计算机技术—控制科学与工程]

 