Use of HPHT Autoclave to Determine Corrosion Inhibition Effect of Poly(methyl methacrylate-co-N-vinyl-2-pyrrolidone) on Carbon Steels in 3.5% NaCl Solution Saturated with CO_2  被引量:1

Use of HPHT Autoclave to Determine Corrosion Inhibition Effect of Poly(methyl methacrylate-co-N-vinyl-2-pyrrolidone) on Carbon Steels in 3.5% NaCl Solution Saturated with CO_2

在线阅读下载全文

作  者:Ambrish Singh 林元华 Chun-yang Zhu Yuan-peng Wu Eno E.Ebenso 

机构地区:[1]State Key Laboratory of Oil and Gas Reservoir Geology and Exploitation, Southwest Petroleum University [2]Department of Chemistry, School of Civil Engineering, LFTS, Lovely Professional University [3]School of Material Science and Engineering (Southwest Petroleum University) [4]Department of Chemistry, School of Mathematical & Physical Sciences, North-West University(Mafikeng Campus)

出  处:《Chinese Journal of Polymer Science》2015年第2期339-348,共10页高分子科学(英文版)

基  金:financially supported by the post doctoral fellowship;the National Natural Science Foundation of China(No.51274170);the research grants from the Open Fund of Southwest Petroleum University(No.X151514KCL32)

摘  要:The influence of poly(methylmethacrylate-co-N-vinyl-2-pyrrolidone), P(MMA-co-VP), on corrosion of carbon steels(J55, N80, P110 SS and C110 steels) in 3.5 wt% NaCl solution saturated with CO2 was evaluated using static high pressure and high temperature(HPHT) autoclave. The surface was further evaluated by X-ray diffraction(XRD), scanning electron microscopy(SEM) and contact angle measurements. Quantum chemical calculations have been used to evaluate the structural, electronic and reactivity parameters of the inhibitor on the steels surface. SEM, XRD and contact angle measurement studies reveal that the surface of metals are quite unaffected after use of inhibitor in 3.5% NaCl solution saturated with CO2.The influence of poly(methylmethacrylate-co-N-vinyl-2-pyrrolidone), P(MMA-co-VP), on corrosion of carbon steels(J55, N80, P110 SS and C110 steels) in 3.5 wt% NaCl solution saturated with CO2 was evaluated using static high pressure and high temperature(HPHT) autoclave. The surface was further evaluated by X-ray diffraction(XRD), scanning electron microscopy(SEM) and contact angle measurements. Quantum chemical calculations have been used to evaluate the structural, electronic and reactivity parameters of the inhibitor on the steels surface. SEM, XRD and contact angle measurement studies reveal that the surface of metals are quite unaffected after use of inhibitor in 3.5% NaCl solution saturated with CO2.

关 键 词:Polymer NMR AUTOCLAVE SEM XRD 

分 类 号:TQ317[化学工程—高聚物工业] TE980[石油与天然气工程—石油机械设备]

 