机构地区:[1]泸州医学院附属医院检验科,四川省泸州市646000
出 处:《临床合理用药杂志》2015年第2期44-45,共2页Chinese Journal of Clinical Rational Drug Use
摘 要:目的探讨AX4030全自动尿液干化仪检测白细胞、红细胞和人工显微镜检查的符合情况。方法随机收集1000份来自医院门诊患者新鲜尿标本,混匀尿液后,分成A、B两管,A管用于干化学分析,B管按10ml刻度定容后,以1500r/min,离心5min,吸掉上清液,留0.2ml沉渣滴于载玻片上进行显微镜下镜检。结果白细胞符合率为91.7%,红细胞符合率为87.6%。以人工显微检查为标准,干化学分析法检查白细胞假阳性率为2.47%,假阴性率为7.54%,而干化学法检查红细胞假阳性率为12.4%,假阴性率为2.16%。结论尿液干化学分析法不能替代镜检法对尿液白细胞、红细胞进行检测。Objective To compare the consistent degree of the AX4030 completely automatic urine dry chemical an-alyzer with white blood cell,the red blood cell and the artificial microscopy. Methods 1000 fresh urine samples from outpa-tients in our hospital were randomly selected and divided into A,B two groups. The group A was used for dry chemical analy-sis. After metered volume according to the 10ml scale,the group B was centrifuged for 5 minutes(1500R/ MIN),absorbing the supernatant,stay 0. 2ml sediment drops to slide on the micro microscopic for examination. Results The coincidence rate of white blood cells was 91. 7% ,and the coincidence rate of red blood cells was 87. 6% . Artificial microscopy as the standard,the false positive rate of white blood cells was 2. 47% with dry chemistry method,while the false negative rate was 7. 54% . The false positive rate of red blood cells was 12. 4% with dry chemistry method,and the false negative rate 2. 16% . Conclusion The urine dry chemical method can not substitute the microscopy in the detection of WBC,RBC .
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.17.37.233