检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Cecilia Mariana Peralta Liliana Patricia Fernndez
机构地区:[1]Instituto de Químrica de San Luis (INQUISAL-CONICET), 5700 San Luis, Argentina [2]rea de Qui mica Fisica, Facultacl de Química,Bioquímica y Farmacia, Chacabuco y Pedemera,Universidaci Nacional de San Luis, 5700 San Luis, Argentina [3]reci de Qufmica Analítica, Facultacl de Química, Bioquímica y Farmacia, Chacabuco y Pedemera,Universidad Nacional de San Luis, 5700 San Luis, Argentina
出 处:《Journal of Pharmaceutical Analysis》2014年第6期368-373,共6页药物分析学报(英文版)
基 金:the National University of San Luis(Project 22/Q228);INQUISAL-CONICET(Instituto de Quimica de San Luis-Consejo Nacional de Investigaciones Cientificas y Tecnicas, PIP-CONICET 11220100100405) for the financial support
摘 要:A simple,eco-friendly.sensitive and economic flow injection spectrofluorimetric method was developed for the determination of O-(β-hydroxyethyl)rutosidcs.The procedure was based on the use of an anionic surfactant such as sodium dodecyl sulfate to provide an appreciable O-(β-hydroxyethyl)rutosides fluorescence enhancement,increasing considerably the sensitivity of detection.All the variables affecting the fluorescence intensity were studied and optimized.The flow rate was 5 mL/min with detection at 450 nm(after excitation at 346 nm).A linear correlation between drug amount and peak area was established for 0-(β-hydroxyethyl)rulosides in the range of 0.01-200 μg/mL with a detection limit of0.001 μg/mL(s/n = 3).Validation processes were performed by recovering studies with satisfactory results.The new methodology can be employed for the routine analysis of 0-(P-hydroxyethyl)rutosides in bulks as well as in commercial formulations.A simple,eco-friendly.sensitive and economic flow injection spectrofluorimetric method was developed for the determination of O-(β-hydroxyethyl)rutosidcs.The procedure was based on the use of an anionic surfactant such as sodium dodecyl sulfate to provide an appreciable O-(β-hydroxyethyl)rutosides fluorescence enhancement,increasing considerably the sensitivity of detection.All the variables affecting the fluorescence intensity were studied and optimized.The flow rate was 5 mL/min with detection at 450 nm(after excitation at 346 nm).A linear correlation between drug amount and peak area was established for 0-(β-hydroxyethyl)rulosides in the range of 0.01-200 μg/mL with a detection limit of0.001 μg/mL(s/n = 3).Validation processes were performed by recovering studies with satisfactory results.The new methodology can be employed for the routine analysis of 0-(P-hydroxyethyl)rutosides in bulks as well as in commercial formulations.
关 键 词:O-(β-hydroxyethyl)rutosides Micellar enhancement Flow injection SPECTROFLUORIMETRY Pharmaceuticals
分 类 号:R917[医药卫生—药物分析学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.149.249.113