O-(β-hydroxyethyl)rutosides determination by micellar flow injection(FI)-spectrofluorimetry  

O-(β-hydroxyethyl)rutosides determination by micellar flow injection(FI)-spectrofluorimetry

在线阅读下载全文

作  者:Cecilia Mariana Peralta Liliana Patricia Fernndez 

机构地区:[1]Instituto de Químrica de San Luis (INQUISAL-CONICET), 5700 San Luis, Argentina [2]rea de Qui mica Fisica, Facultacl de Química,Bioquímica y Farmacia, Chacabuco y Pedemera,Universidaci Nacional de San Luis, 5700 San Luis, Argentina [3]reci de Qufmica Analítica, Facultacl de Química, Bioquímica y Farmacia, Chacabuco y Pedemera,Universidad Nacional de San Luis, 5700 San Luis, Argentina

出  处:《Journal of Pharmaceutical Analysis》2014年第6期368-373,共6页药物分析学报(英文版)

基  金:the National University of San Luis(Project 22/Q228);INQUISAL-CONICET(Instituto de Quimica de San Luis-Consejo Nacional de Investigaciones Cientificas y Tecnicas, PIP-CONICET 11220100100405) for the financial support

摘  要:A simple,eco-friendly.sensitive and economic flow injection spectrofluorimetric method was developed for the determination of O-(β-hydroxyethyl)rutosidcs.The procedure was based on the use of an anionic surfactant such as sodium dodecyl sulfate to provide an appreciable O-(β-hydroxyethyl)rutosides fluorescence enhancement,increasing considerably the sensitivity of detection.All the variables affecting the fluorescence intensity were studied and optimized.The flow rate was 5 mL/min with detection at 450 nm(after excitation at 346 nm).A linear correlation between drug amount and peak area was established for 0-(β-hydroxyethyl)rulosides in the range of 0.01-200 μg/mL with a detection limit of0.001 μg/mL(s/n = 3).Validation processes were performed by recovering studies with satisfactory results.The new methodology can be employed for the routine analysis of 0-(P-hydroxyethyl)rutosides in bulks as well as in commercial formulations.A simple,eco-friendly.sensitive and economic flow injection spectrofluorimetric method was developed for the determination of O-(β-hydroxyethyl)rutosidcs.The procedure was based on the use of an anionic surfactant such as sodium dodecyl sulfate to provide an appreciable O-(β-hydroxyethyl)rutosides fluorescence enhancement,increasing considerably the sensitivity of detection.All the variables affecting the fluorescence intensity were studied and optimized.The flow rate was 5 mL/min with detection at 450 nm(after excitation at 346 nm).A linear correlation between drug amount and peak area was established for 0-(β-hydroxyethyl)rulosides in the range of 0.01-200 μg/mL with a detection limit of0.001 μg/mL(s/n = 3).Validation processes were performed by recovering studies with satisfactory results.The new methodology can be employed for the routine analysis of 0-(P-hydroxyethyl)rutosides in bulks as well as in commercial formulations.

关 键 词:O-(β-hydroxyethyl)rutosides Micellar enhancement Flow injection SPECTROFLUORIMETRY Pharmaceuticals 

分 类 号:R917[医药卫生—药物分析学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象