检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:余真[1] 马嵩源[1] 刘乃锁[1] 陈光[1] 李浩[1]
机构地区:[1]天津电气传动设计研究所有限公司,天津300180
出 处:《电气传动》2014年第12期82-85,共4页Electric Drive
摘 要:灭磁系统是发电机励磁系统的重要保护设施,是发电机内部短路故障时减小损失的唯一方法。在试验站励磁系统中,灭磁系统要求必须快速可靠,这样才能在各种事故中保护励磁线圈和整流装置。在该系统中,采用逆变灭磁,强制灭磁和自动灭磁几个级别,分别用继电器,PLC控制的组合方式来应对几个需要灭磁的特殊情况,提高了灭磁保护的可靠性,对灭磁开关的触点也有比较好的保护。在发电机型式试验站的实际使用中,效果良好。De-excitation system is the important protection facility of generator excitation system , is the only method to reduce losses of generator internal fanlt. In the excitation system, de-excitation system is required fast and reliably, it can protect the excitation coil and rectifier device in a variety of accidents. In de-excitation system, the inverter de-excitation, forced de-excitation and automatic de-excitation several levels were used, combination of relay and PLC control was used to deal with several special cases of de-excitation. The reliability of de-excitation protection is improved, the magnetic switch contact is also quite good protected. In the actual use of generator test station, results are good.