空压机停机事故原因分析及改造对策  

Air Compressor Shutdown Accident Analysis and Countermeasures

在线阅读下载全文

作  者:徐春霞[1] 王晓兵[2] 杨立平[2] 王相军[2] 葛跃田[1] 

机构地区:[1]克拉玛依职业技术学院电子与电气工程系,新疆独山子833600 [2]新疆独山子石化公司,新疆独山子833600

出  处:《电气传动》2014年第12期90-92,共3页Electric Drive

摘  要:结合现场实例解决了由于空压机的油泵电动机控制电路中电气元件选用及电缆安装时忽略电磁兼容性的概念,造成空压机停机事故发生的问题。首先介绍了空压机的工作概况,其次通过故障现象的观察以及相应的检查测试,分析给出了明确的故障原因,最后综合考虑各种因素提出了合理的整改方案。改造完成后,空压机运行稳定,满足生产要求。Combined with the practical examples solved that, due to oil pump motor of compressor control ignore problems of electromagnetic compatibility of electrical components selection and cable installation circuit, causes the air compressor shutdown accident problem. Firstly introduced the working of air compressor, then through observation of fault phenomenon and the corresponding examination test, analyaed the fault reason clear, finally considering various factors of the improvement is put forward reasonable. After the completion of the transformation, the air compressor operating stability, meet the requirement of production.

关 键 词:电磁兼容性 空压机 电子式时间继电器 感应电压 屏蔽电缆 

分 类 号:TM506[电气工程—电器]

 