某电厂220MW机组接长轴振动故障诊断及处理  被引量:1

Vibration Diagnosis and Disposal of Extended Shaft for 220MW Unit of One Power Plant

在线阅读下载全文

作  者:张红 刘树鹏[2] 张卫军[2] 

机构地区:[1]国电靖远发电有限公司,甘肃白银730919 [2]西安热工研究院有限公司汽轮机及热力系统技术部,陕西西安710032

出  处:《发电与空调》2014年第6期28-31,共4页

摘  要:某电厂220MW机组3号轴承相对轴振动和座振动均超标。通过分析历史数据,诊断振动原因为:中-低压转子中间接长轴设计结构薄弱,机组甩负荷停机使得接长轴产生了较大地二阶质量不平衡。通过采用现场高速动平衡技术,在接长轴上加重,降低相关测点振动值,使机组振动达到优良水平。The 3th relative shaft vibration and bearing vibration have been exceeded standard. By analyzing the his-torical data,diagnosed the vibrational reasons are that the design structure of the extended shaft is weak and then load shed-ding made the extended shaft produced greatly second-order mass imbalance. Through adopting field dynamic balancing method,the trial weights were added onto the extended shaft to reduce the 3th relative shaft vibration and bearing vibration. The unit vibrations eventually were controlled to a satisfied level.

关 键 词:220MW汽轮发电机组 接长轴 振动 动平衡 

分 类 号:TM311[电气工程—电机]

 