1100kV瓷套型避雷器机械应力仿真分析  被引量:5

Mechanical Stresses Simulation of 1 100 kV Porcelain Housed Surge Arresters

在线阅读下载全文

作  者:刘朝丰[1] 李西育[1] 王卫国 施毅舟[1] 魏劲容[1] 党镇平[1] 

机构地区:[1]西安1西安高压电器研究院有限责任公司,西安710077 [2]西安西电高压电瓷有限责任公司,西安710077

出  处:《电瓷避雷器》2015年第1期148-154,共7页Insulators and Surge Arresters

摘  要:根据1 100 kV瓷套型避雷器机械性能要求,从力学分析角度,建立瓷套型避雷器的静力学和动力学分析模型,采用有限元法进行静力弯曲试验和动力学仿真分析。静力学、动力学仿真计算数据与产品试验数据的对比研究表明:静力学、动力学仿真计算建模及计算方法准确;1 100 kV瓷套型避雷器设计满足工程需求。The static and dynamic analysis models of 1100 kV porcelain housed surge arresters are established according to its mechanical requirements. The static bending test and dynamic simulation analysis are carried out based on finite element method. The comparison of the statics, dynamics simulation calculation data and the product experimental data show that the statics and dynamics simulation calculation modeling and calculation method are accurate; the design of 1 100 kV porcelain housed surge arresters can meet the project requirement.

关 键 词:瓷套型避雷器 机械应力 有限元分析 静力学分析 动力学分析 

分 类 号:TM862[电气工程—高电压与绝缘技术]

 