基于Tabu算法的配电网无功补偿  被引量:21

Reactive Compensation of Distribution Networks Based on Tabu Algorithm

在线阅读下载全文

作  者:高迪[1] 路瑶 赵娟娟[1] 郭志成[1] 

机构地区:[1]兰州工业学院电气工程学院,甘肃兰州730050 [2]国网渭南供电公司,陕西渭南714000

出  处:《电气自动化》2015年第1期91-93,共3页Electrical Automation

摘  要:配电网最优无功补偿主要考虑最优补偿容量的确定、最优补偿设备的分布等问题,来降低网络损耗,提高系统的电能质量。针对目前配电网的无功补偿问题,采用禁忌搜索算法,通过扩大邻域搜索范围,利用IEEE69节点进行算例分析,从而实现系统无功功率补偿的全局最优状态。For the optimal reactive compensation of distribution networks, among main considerations are determination of optimal compensation capacity and distribution of optimal compensation devices, aiming at reducing network loss and improving the electric power quality. In view of existing reactive compensation of distribution networks, the Tabu search algorithm is adopted, so that the neighborhood search scope is expanded and IEEE69 node is used for analysis of example so as to achieve the global optimal state of reactive compensation of the system.

关 键 词:配电网 Tabu 无功补偿 优化规划 电容器组 