350MW新建超临界锅炉结渣原因分析与初步调整措施  被引量:3

Cause Analysis and Preliminary Adjustment Measures of Slagging on Newly-built 350MW Supercritical Boiler

在线阅读下载全文

作  者:牟晓哲[1] 周江博[1] 韩昕[1] 范景扬 

机构地区:[1]华北电力科学研究院有限责任公司 [2]内蒙古京能康巴什热电有限公司

出  处:《电站系统工程》2015年第1期26-28,共3页Power System Engineering

摘  要:某厂350 MW新建超临界锅炉由于燃用煤质与设计偏差大,影响炉内燃烧,造成锅炉结渣严重,不利于锅炉的安全、稳定运行。通过分析结渣原因,采用初步的燃烧调整探索合理工况,同时提出了进一步优化的对策,为同类型锅炉基建调试及投产后防治锅炉结渣现象提供参考。Significant difference between the real and designed coal for a newly-built 350MW supercritical boiler affects the furnace combustion and leads to serious slagging on water wall, which will do harm to the secure and stable operation of the boiler. On the basis of cause analysis of slagging, preliminary adjustment measures are taken to explore the reasonable condition and methods for further optimization are proposed simultaneously, which can be used as a reference for slagging prevention of the same type of boilers.

关 键 词:超临界锅炉 结渣 非设计煤种 切圆燃烧 

分 类 号:TK227.2[动力工程及工程热物理—动力机械及工程]

 