不同离子膜在膜极距槽的运行情况  

Working conditions of different ion-exchange membranes in membrane-thickness electrode-distance electrolyzers

在线阅读下载全文

作  者:张中华[1] 陈建华[1] 

机构地区:[1]中盐湖南株洲化工集团有限公司,湖南株洲412004

出  处:《氯碱工业》2015年第1期10-12,共3页Chlor-Alkali Industry

摘  要:分别由甲、乙两个公司将离子膜电解槽改造成膜极距槽。改造后,不同厂家改造的电解槽分别使用X、Y离子膜,对比运行数据,发现:X膜的膜阻较小,膜压降低;Y膜的膜阻较大,膜压降较高;甲公司改造的膜极距槽整体质量较高,其阳极涂层配方略差;乙公司改造的膜极距槽节电性能略差,但阳极涂层配方较好。Ion-exchange membrane electrolyzers were remodeled into membrane-thickness electrodedistance ones by company A and B respectively. The remodeled electrolyzers used ion-exchange membrane X and Y. The running data showed:( 1) membrane X had small resistance and low voltage drop;( 2) membrane Y had big resistance and high voltage drop;( 3) the electrolyzers remodeled by company A had good overall quality,but its anode coating performance was poor slightly;( 4) the electrolyzers remodeled by company B had little poor electricity-saving effect,but its anode coating performance was better.

关 键 词:烧碱 膜极距电解槽 离子膜 

分 类 号:TQ114.262[化学工程—无机化工]

 