摘  要:为改善苏州市姑苏区污水管道运行能力,提升福星污水处理厂污水处理效率,以及掌握该区域污水管道健康状况,结合CCTV检测技术对苏州市姑苏区宝带西路、南环西路、桐径北路、福运路、西环路段总长度约10.19km市政污水管道开展检测、评估、维护工作。实践表明,该地区污水管道经过维护后,排污能力有明显提升。To improve the capacity of the sewer system in Gusu District of Suzhou City, enhance the treatment efficiency of the Fuxing Wastewater Treatment Plant, and understand the current condition of the sewer system of this area, a investigation, evaluation, and maintenance project of the municipal sewer pipe of Baodai West Road, Nanhuan West Road, Tongjing North Road, Fuyun Road and Xihuan road with the total length of about 10. 19 km was carried out by using the CCTV detecting technology. The results showed that the drainage capacity of this sewer system was improved greatly after the maintenance.