检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:陈正锋
机构地区:[1]大同煤矿集团宏远工程建设有限责任公司,山西大同037003
出 处:《山西焦煤科技》2015年第1期43-45,共3页Shanxi Coking Coal Science & Technology
摘 要:在矿山基本建设中,矿区变电所、风井场地及瓦斯抽放泵站等建(构)筑物一般建设在山区上,该区域气候干燥,雨水少,地质以岩石为主,场区传统的水平式接地网接地电阻满足不了设计规范要求,故如何降低场区接地电阻,长期有效地保证场区设备及人身安全,显得尤为重要。介绍了岩石丘陵地区的室外防雷接地施工应用情况,通过实例对垂直式深井接地与传统的水平式接地的实用性进行了比较,验证了岩石地区采用深井接地的经济性和可靠性,符合国内岩石丘陵地区室外接地网施工、改造的发展趋势。In the basic construction of coal mine,the buildings such as mine substation,ventilation shaft site, gas drainage pumping station and others are usually in the mountains area.The climate of the region is dry and less rain,rock is the main geology.In the areas,it can't satisfy the design specification requirement of horizontal ground-ing network grounding resistance in tradition,so it is particularly important that how to reduce the ground resistance and chronically and effectively ensure the safety of equipment and person in court areas.Introduces the application situation of outdoor lightning protection construction in rock hilly region.The practicability of vertical deep well grounding and horizontal grounding in tradition are compared by living example.Verifies the economy and reliability of deep well grounding in rock hilly region,it conforms to construction and reconstruction trend of outdoor grounding grid in domestic rock hilly region.