检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:包素萍[1] 顾爱国[1] 王莉[1] 武中平[1] 朱利利[1] 曹磊[1]
机构地区:[1]江苏省产品质量监督检验研究院,南京210007
出 处:《现代农药》2015年第1期21-23,34,共4页MODERN AGROCHEMICALS
摘 要:建立草甘膦钾盐水剂的鉴别检测方法。以5 mmol/L甲磺酸水溶液为流动相,采用CS 12A离子色谱柱(含CG 12A保护柱)以及电导检测器对草甘膦钾盐水剂中的钾离子进行鉴别检测。结果表明:方法线性相关系数为0.999 9,标准偏差小于0.1,变异系数小于1.0%,平均回收率为100.65%。该方法能够用于鉴别检测草甘膦钾盐水剂的有效成分。The discrimination method of glyphosate-potassium AS was established by Ion Chromatography (IC) using 5 mmol/L methanesulfonic acid aqueous solution as the mobile phase, CS 12A ion column (including CG 12A guard column) and conductivity detector. The results showed that the linear correlation coefficient of the method was 0.999 9, the standard deviation was less than 0.1, the coefficient of variation was less than 1.0%, the average recovery was 100.65%. The method was precise, accurate and simple, could be used to discriminate the active ingredient in glyphosate- potassium AS.