基于负序分量和模糊逻辑相融合的永磁同步电机定子不对称故障诊断  被引量:4

Stator Asymmetry Fault Diagnosis of PMSM Based on Combination of Negative Sequence Component and Fuzzy Logic

在线阅读下载全文

作  者:张志艳[1,2] 马宏忠[1] 赵剑锷[3] 赵利军 

机构地区:[1]河海大学能源与电气学院,江苏南京211100 [2]郑州轻工业学院电气信息工程学院,河南郑州450002 [3]郑州科技学院电气工程学院,河南郑州450064 [4]国家电网平高集团有限公司,河南平顶山467001

出  处:《电机与控制应用》2014年第6期64-68,共5页Electric machines & control application

基  金:国家自然科学基金(51177039);上海汽车工业科技发展基金会基金(1106)

摘  要:采集永磁同步电机定子不对称故障状态下的三相电流和三相电压,在对其进行FFT分析,利用不对称分量的对称分量法计算其基波负序分量。构建了模糊故障诊断中心,对实测数据进行了分析。结果表明,负序分量和模糊逻辑相融合的诊断方法能够准确有效对永磁同步电机定子不对称故障进行诊断。Three-phase current and voltage data of permanent magnet synchronous motor( PMSM) stator were collected under asymmetry fault condition,and were analyzed by fast Fourier transformation( FFT). Fundamental negative sequence components were gained using symmetric analysis method of asymmetric component. Fuzzy logic fault diagnosis center was constructed,and actual measured data were analyzed. The experimental data analysis results show that the diagnosis method by combination of negative sequence component and fuzzy logic can be accurate and effective diagnosis of PMSM asymmetric fault.

关 键 词:永磁同步电机 不对称 故障诊断 负序分量 模糊逻辑 

分 类 号:TM351[电气工程—电机] TM307.1

 