600MW机组真空泵工作液强制冷却装置技术改造  被引量:1

Installation Transformation of Forced Cooling Device for Working Fluid of Vacuum Pump on 600 MW Unit

在线阅读下载全文

作  者:赵则飞 徐浩 

机构地区:[1]华电内蒙古能源有限公司包头发电分公司,内蒙古包头014013

出  处:《内蒙古电力技术》2015年第1期53-56,共4页Inner Mongolia Electric Power

摘  要:某电厂600 MW机组存在夏季真空低、真空泵易发生汽蚀等问题,实施了真空泵工作液外加强制冷却装置的技术改造。改造后可保证工作液温度达到设计值,夏季负荷为596MW工况下机组真空提高了约0.67 k Pa,煤耗率下降约1.9 g/k Wh,经济效益显著。One 600 MW unit in a power plant, vacuum was low and vacuum pump prone to cavitation in summer, technology transformation was conducted that a forced cooling device for working liquid of vacuum pump was applied. The transformation, could ensure the working fluid temperature to meet the designed value, in summer, unit vacuum had increased about 0.67 kPa when unit load was 596 MW, the coal consumption rate fell by about 1.9 g/kWh, economic benefit was significant.

关 键 词:真空泵工作液 溴化锂制冷机 凝汽器抽空气系统 汽蚀 

分 类 号:TK264.14[动力工程及工程热物理—动力机械及工程]

 