检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]三峡库区生态环境教育部重点试验室(重庆大学) [2]中国建筑西南设计研究院有限公司
出 处:《哈尔滨工业大学学报》2015年第2期92-97,共6页Journal of Harbin Institute of Technology
基 金:国家自然科学基金(51178482)
摘 要:为了改进竖直埋管岩土换热器型式的换热性能,提出减小换热器热阻的结构改进设计方案,由三根进水管和一根较大管径的保温出水管构成.推导了结构改进后的换热器热阻理论计算式,计算结果表明,改进后换热器的热阻值比单U和双U型明显减小.在深度约96 m的钻孔内对改进型换热器和单U型、双U型换热器进行了多组加载热负荷试验,结果显示:改进后换热器的热阻比单U型减小29%-34%,比双U型减小10%-15%;系统循环水温升比双U型平均小1.5℃,换热性能有较明显提高.Based on the deficiencies of existing ground heat exchangers,a new type energy-storage heat exchanger is proposed,which consists of three inlet pipes and one thermal insulation outlet pipe. Thermal resistance of this new type heat exchanger is calculated,which shows a much smaller value over conventional ones. Experimental measurements to evaluate the performance of single-U,double-U and the new design,were carried out in boreholes about 96 meters deep,which showed superior performance of the new type. The thermal resistance of the new type was 29%-34% and 10%-15% smaller than that of single-U and double-U respectively. The circulation water temperature rise of new type was 1.5 ℃ lower than double-U.
分 类 号:TK02[动力工程及工程热物理]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.147.103.209