Y型留置针行桡动脉穿刺术的应用  被引量:2

The Application of Y- shaped Detained Needle in Radial Artery Puncturing

在线阅读下载全文

作  者:田学峰[1] 王政[1] 潘惠利[1] 张悦[1] 孙艳[1] 

机构地区:[1]黑龙江省医院,黑龙江哈尔滨150000

出  处:《中西医结合心血管病电子杂志》2014年第14期60-61,共2页Cardiovascular Disease Electronic Journal of Integrated Traditional Chinese and Western Medicine

基  金:黑龙江省医院新技术项目

摘  要:目的探讨Y型留置针应用于桡动脉穿刺的优势。方法选择100例需行桡动脉穿刺行介入治疗,分为两组,各50例。试验组采用Y型留置针置管法,对照组采用动脉穿刺针传统操作法观察两组操作一次性成功率以及穿刺时造成血液污染。结果一次穿刺成功率试验组明显高于对照组,差异具有统计学意义(P<0.05);血液污染情况试验组明显少于对照组,差异具有统计学意义(P<0.05)。结论用Y型留置针行桡动脉穿刺一次性穿刺成功率高,同时减少由血液溢出造成的污染。Objective To Investigate the advantage of Y-shaped detained needle in radial artery puncturing. Methods 100 patients with Percutaneous coronary intervention(PCI), divide into two groops: the study group (group A)using Y-shaped detained needle catheterize, the second group(groupB) using arterial needle in traditional way.The one-time success rate and the blood contamination by blood spilling during operation in each group were observed. Results There was no signiifcant difference in Age, gender, weight and blood pressure during puncture in the two groups (P〉0.05). The one-time success rate was much lower in the study group than the conctrol (P〈0.05), while the blood contamination were lower in study groop than group B (P〈0.05).Conclusion Using of Y-shaped Detained needle catheterize in radial artery puncture can improve the one-time success rate, and reduce the blood contamination by blood spilling.

关 键 词:Y型留置针 桡动脉穿刺 介入治疗 

分 类 号:R45[医药卫生—治疗学]

 