检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
出 处:《现代检验医学杂志》2015年第1期108-110,共3页Journal of Modern Laboratory Medicine
摘 要:目的:通过研究两种不同试剂 D-二聚体(D-DIMER)检测值与纤维蛋白降解产物(fibrin degradation products, FDP)的相关性,分析检测值的吻合度,评价两种检测试剂的临床实用性。方法采用Sysmex CA-1500全自动血凝分析仪检测患者D-二聚体及 FDP,D-二聚体检测试剂分别为 Siemens Innovance D-DIMER和 Dade Behring D-Dimer Plus。回顾性研究762例临床患者标本D-二聚体及 FDP测定结果,并将测定结果进行等级频数分析及等级相关检验(Spearman法)。结果 Siemens Innovance D-DIMER试剂检测同一患者D-二聚体值与 FDP水平呈正相关(r=0.954,P<0.01),优于 Siemens DD Plus试剂(r=0.885,P<0.01),且这种相关性随D-二聚体含量的升高而升高,当D-二聚体>5 mg/L FEU时,相关性达到最佳(P<0.01)。Innovance D-DIMER试剂组 FDP阳性率(约为65.76%)相对于 DD Plus试剂组(91.48%)偏低,提示 Innovance D-DIMER试剂组D-二聚体能够在 FDP升高之前出现反应,具有更高的灵敏度。结论使用 Siemens Innovance D-DIMER试剂检测D-二聚体并结合 FDP值可以为临床提供更加确切的疾病诊治信息。Objective To evaluate the clinical practicality of two different D-dimer assays by studying the correlation of the testing results by two different D-dimer reagents with fibrin degradation products (FDP)result values and analyzing the Clinical alignment.Methods A representative cross-sectional study of 762 clinical patients’plasma specimens were taken to measure the results of D-dimer and FDP by using Sysmex CA-1500 automated coagulation analyzer,D-DIMER detection reagent respectively Siemens Innovance D-DIMER and Dade Behring D-DIMER Plus reagents.Then rating frequency analysis and Spearman correlation test were applied to analyze the correlation of measurement results.Results Overall,to the same patient,the correlation of D-dimer tested by Siemens Innovance D-DIMER Reagent with FDP level was significant positive (r= 0.954,P〈0.01),better than that tested by Siemens DD Plus Reagent (r=0.885,P〈0.01);and this correlation had an increasing trend when D-dimer level raised.When D-dimer level 〉 5 mg/L FEU,the correlation was the best (P〈0.01). And by calculating the amount of positive FDP (FDP〉5μg/ml)and FDP positive rate in both different cases when D-dimer results was also positive,FDP positive rate in Innovance D-DIMER Reagent group (about 65.76%)was lower than DD Plus Reagent group,it indicated that D-dimer results tested by Innovance D-DIMER Reagent could raise before FDP reacted,so D-dimer had a higher sensitivity than FDP.Conclusion It can provide a more precise clinical diagnosis and treatment information when using Siemens Innovance D-DIMER Reagent to detect D-dimer values and combined FDP values at the same time.
关 键 词:D-二聚体 纤维蛋白降解产物P SIEMENS D-DIMER Plus试剂 Innovance D-DIMER试剂
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.17.179.20