Data acquisition and control system for lead-bismuth loop KYLIN-Ⅱ-M  

Data acquisition and control system for lead-bismuth loop KYLIN-Ⅱ-M

在线阅读下载全文

作  者:姚传明 黄群英 朱志强 李洋 贺建 

机构地区:[1]University of Science and Technology of China [2]Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences

出  处:《Nuclear Science and Techniques》2015年第1期25-32,共8页核技术(英文)

基  金:Supported by the Accelerator Driven Systems Project of the Chinese Academy of Sciences(No.XDA03040000)

摘  要:Among different heavy liquid metals(HLMs), lead-bismuth eutectic(LBE) is considered at present as a potential candidate for the coolant of new generation fast reactors(critical and subcritical) and for liquid spallation neutron sources and accelerator driven systems(ADS). A high temperature liquid LBE loop, KYLIN-II-M,has been built to study the characteristics of corrosion and fluidity of LBE at the Institute of Nuclear Energy Safety Technology. However, due to the sensors and execution components of the loop work at high temperatures and in severely corrosive environments, the reliability and security of the data acquisition and control system(DACS) of KYLIN-II-M face challenges during the loop operation. In order to meet the urgent needs for KYLIN-II-M's long-term stable operation, a virtualization and redundancy control system has been developed.The onsite operation result shows that the DACS is stable and reliable. In this paper, the experimental results are described in detail.Among different heavy liquid metals (HLMs), lead-bismuth eutectic (LBE) is considered at present as a po- tential candidate for the coolant of new generation fast reactors (critical and subcritical) and for liquid spallation neutron sources and accelerator driven systems (ADS). A high temperature liquid LBE loop, KYLIN-II-M, has been built to study the characteristics of corrosion and fluidity of LBE at the Institute of Nuclear Energy Safety Technology. However, due to the sensors and execution components of the loop work at high temper- atures and in severely corrosive environments, the reliability and security of the data acquisition and control system (DACS) of KYLIN-II-M face challenges during the loop operation. In order to meet the urgent needs for KYLIN-II-M's long-term stable operation, a virtualization and redundancy control system has been developed. The onsite operation result shows that the DACS is stable and reliable. In this paper, the experimental results are described in detail.

关 键 词:冗余控制系统 数据采集 加速器驱动系统 回路   液体金属 液体循环 

分 类 号:TL353[核科学技术—核技术及应用]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象