检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]上海理工大学能源与动力工程学院,上海200093
出 处:《广州化学》2015年第1期19-24,共6页Guangzhou Chemistry
摘 要:简要介绍了闪蒸补汽式余热发电技术,采用动态优化方法优化余热锅炉主汽及闪蒸补汽的运行参数。根据建立的热力计算模型,得到主蒸汽压力随窄点温差、接近点温差、热端温差等设计变量的变化规律曲线。以马钢320 m2、400 000 t/h烧结机为例,烧结余热发电闪蒸系统主蒸汽压力应选在2.35 MPa,闪蒸压力应选在0.25 MPa为最佳,闪蒸补气式余热发电系统优化前后的年经济效益可增加36.222万元,比优化前CO2排量减少0.063 6万吨,节省标煤量270.4吨。Flash compensation-gas waste heat power generation technology was introduced. The dynamic optimization method was used to optimize main-steam and flash steam parameters. According to thermodynamic calculation model, variable curves of design parameters, such as main-steam pressure with pinch point temperature difference, approach point temperature difference, warm-end temperature difference were got. Taking 320 m2、400 000 t/h sintering cooling machine of MA STEEL for an example, the best steam system main-steam pressure should select 2.35 MPa, flash pressure 0.25 MPa. Flash compensation-gas waste heat power generation technology optimization statistics before and after years increased by 362,220 Yuan, cut CO2 emissions of 636 tons, saving standard coal 270.4 tons.
分 类 号:TK115[动力工程及工程热物理—热能工程]