ABR+生物接触氧化法处理高浓度有毒有机废水  被引量:3

High-concentrated Organic and Poisoning Wastewater Treatment by ABR and Biological Contact Oxidation Combined Process

在线阅读下载全文

作  者:郭蒙蒙[1] 戴博文[1] 赵思远 赵贤广[1] 徐炎华[1] 

机构地区:[1]南京工业大学环境学院,南京210009 [2]南化集团研究院,南京210048

出  处:《工业安全与环保》2015年第2期16-18,共3页Industrial Safety and Environmental Protection

摘  要:本文采用ABR+生物接触氧化组合工艺处理含苯酚的高COD有毒有机废水,实验研究了ABR反应器的抗毒性及对COD、苯酚和NH3-N的处理效果。实验结果表明:废水COD和苯酚的去除主要发生在厌氧阶段;在苯酚质量浓度1 000 mg/L左右时,ABR反应器和常规厌氧反应器的处理效率均出现明显的下降趋势,但ABR反应器对苯酚的耐受浓度明显高于常规厌氧反应器;相比于常规厌氧反应器,ABR反应器推流式的特性实现了产酸和产甲烷优势菌群的分离,具有较高的COD、苯酚的去除率和较强的抗毒性;对NH3-N的去除,ABR反应器的强化效果不明显。The combined process of ABR and biological contact oxidation is used to treat organic wastewater which contains phenol and high COD. The toxicity- resistance and the removal efficiencies of COD,phenol and NH3- N of ABR have been experimentally studied. The results show that the removal of COD and phenol mainly happens in the anaerobic stage. When the mass concentration of phenol is 1 000 mg / L,the removal efficiencies of COD and phenol of the ABR and traditional anaerobic reactor are both decreased obviously,but the toxicity- resistance ability of ABR reactor is higher than that of the traditional anaerobic reactor. The hydraulic characteristic of ABR makes the acidogenic bacteria and methanogen separated,resulting in its stronger toxicity- resistance ability and higher removal efficiencies of COD and phenol than that of the traditional anaerobic reactor. However,the NH3- N removal efficiency can't be strengthened obviously by the ABR reactor.

关 键 词:ABR反应器 苯酚 有毒废水 厌氧 

分 类 号:X703.1[环境科学与工程—环境工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象