关于室内质控总胆红素漂移的原因分析及解决办法  

Reason analysis and solution method of internal quality total bilirubin drift

在线阅读下载全文

作  者:郑风林 

机构地区:[1]德州市立医院检验科,山东德州253012

出  处:《医学检验与临床》2015年第1期19-21,共3页Medical Laboratory Science and Clinics

摘  要:目的:研究月配质控血清总胆红素(TBIL)测定值随着时间的推移向下漂移的原因及找出解决的办法。方法:把配制的质控血清分别分装在30支普通透明的子弹头状离心管和30支棕褐色避光的离心管中放冰箱冷冻备用,每天取出一支进行质控检测。结果:普通透明离心管保存的质控血清TBIL测定值逐天明显向下漂移,而避光保存的质控血清其TBIL测定值则基本稳定在一个理想的质控允许范围以内。结论:用棕褐色离心管保存质控血清,可有效防止质控血清TBIL测定值的向下漂移。Objective:To study the reason and solution of the down drift of total bilirubin serum prepared monthly. Methods:The prepared quality-control serum was distributed into 30 crystal or brown bullet-shaped tubes respectively, and stored at-20℃. Take out a tube every day for test.Results:The test level of quality-control serum preserved in crystal tubes drift down obviously everyday,while that in brown tubes was stable in a desired range. Conclusions:The down-drift of quality-control serum levels could be prevented effectively by preserved in brown tubes.

关 键 词:总胆红素 漂移 棕褐色离心管 避光保存 

分 类 号:R512.6[医药卫生—内科学]

 