检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:郑风林
出 处:《医学检验与临床》2015年第1期19-21,共3页Medical Laboratory Science and Clinics
摘 要:目的:研究月配质控血清总胆红素(TBIL)测定值随着时间的推移向下漂移的原因及找出解决的办法。方法:把配制的质控血清分别分装在30支普通透明的子弹头状离心管和30支棕褐色避光的离心管中放冰箱冷冻备用,每天取出一支进行质控检测。结果:普通透明离心管保存的质控血清TBIL测定值逐天明显向下漂移,而避光保存的质控血清其TBIL测定值则基本稳定在一个理想的质控允许范围以内。结论:用棕褐色离心管保存质控血清,可有效防止质控血清TBIL测定值的向下漂移。Objective:To study the reason and solution of the down drift of total bilirubin serum prepared monthly. Methods:The prepared quality-control serum was distributed into 30 crystal or brown bullet-shaped tubes respectively, and stored at-20℃. Take out a tube every day for test.Results:The test level of quality-control serum preserved in crystal tubes drift down obviously everyday,while that in brown tubes was stable in a desired range. Conclusions:The down-drift of quality-control serum levels could be prevented effectively by preserved in brown tubes.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222