检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]韶关学院化学与环境工程学院,广东韶关512005
出 处:《韶关学院学报》2015年第2期29-32,共4页Journal of Shaoguan University
基 金:韶关市科技计划项目(201009)
摘 要:建立了火焰原子发射光谱法测定电解质饮料中钾和钠含量的方法.钾、钠的方法检出限分别为0.00422μg/mL和0.00216μg/mL,钾、钠的加标回收率分别为91.1%-100.9%和93.0%-102.8%.该方法操作简单、快速、准确度高、重现性好、无需使用附加光源,测定结果与火焰原子吸收光谱法无显著性差异.A method was established for determination of potassium and sodium contents in electrolyte drink by flame atomic emission spectrometry (FAES). The detection limits of K and Na were 0.004 22μg/mL and 0.002 16μg/mL respectively. And the relative standard devitation (RSD) were 91.1%~100.9% and 93.0%~102.8%respectively. The method is simple, rapid, accurate, reproducible, and without using extra light source. Its experimental results are as closely as that of the flame atomic absorption spectrometry (FAAS).