建立乳腺超声BI—RADS评估分类评分标准的初步研究  被引量:19

A detailed criterion of BI-RADS assessment category based on US-BI-RADS: a preliminary study

在线阅读下载全文

作  者:赵海娜[1] 彭玉兰[1] 骆洪浩[1] 何玉霜[1] 金亚[1] 杨盼[1] 

机构地区:[1]四川大学华西医院超声科,成都610041

出  处:《中华超声影像学杂志》2015年第3期242-245,共4页Chinese Journal of Ultrasonography

基  金:四川省科技厅支撑项目(21112SZ0145);成都市科技局(12PPYB053SF-002)

摘  要:目的基于乳腺超声图像特征建立BI—RADs评估分类评分系统,旨在为超声医师提供乳腺超声评估分类的客观依据。方法回顾分析2011年1—9月及2012年1月行乳腺超声检查并经病理证实的1938例女性病例,以21)11年病例为模型病例,通过单因素分析,获得各个超声征象诊断乳腺癌的权重,依据各特征的权重给予相应的赋值,建立评估分类评分标准模型,以乳腺影像报告与数据系统第4版为标准,提出BI—RADS评估分类3类、4类、5类及4类亚类的分类评分标准;最后以2012年病例为测试病例,验证该评分标准的有效性。结果纳入24个BI—RADS征象术语,其中18项差异有统计学意义(P〈0.05)。依据OR值大小,将征象分为大征象、中征象、小征象3类,各类赋值分别为3分、2分、1分,建立评分模型如下:Score=3*(X1+X2+…+X6)+2*(X7+X8+…+X12)+(X9+X10+…+X18),其中X1-X18依次为Cooper韧带受牵拉、强回声晕、皮肤增厚、腋窝淋巴结、结构扭曲、边缘毛刺征、不规则形、模糊、水肿、边界不完整、阻力指数≥0.7、肿块内微钙化、成角、流速≥20cm/s、后方回声衰减、方位不平行、微小分叶、血流分级为Ⅱ级或Ⅲ级。依据BI—RADS标准,假设〈2分为3类,2≤Score〈6分为4A类,6≤Scored10分为4B类,10≤Score〈16分为4C类,≥16分为5类。模型病例与测试病例3类、4A类、4B类、4C类及5类阳性预测值分别为1.5%/1.4%、6.9%/3.4%、22.1%/21.1%、62.5%/69.4%、96.1%/92.7%。结论数据评分系统能够客观评估乳腺肿块B1-RADS标准分类,便于医生间交流和预测乳腺癌危险度。Objective To set up an objective criterion for BI-RADS assessment. Methods The breast sonograms of 1 938 female cases were retrospectively studied which had been confirmed by pathology from January to September 2011 and 2012 January. 1 660 cases during 2011 were model cases, and the importance of each single feature in distinguishing between benign and malignant was obtained with Chi square and OR value. A detailed criterion of BI-RADS assessment category was set up based on US-BI-RADS. Results Eighteen of 24 lexicons were statistically significant distinguished between benign and malignant breast masses( P 〈0.05). The lexicons were divided into major suspicious signs, middle ones and minor ones assigned 3 points,2 points and 1 point,and a scoring model was established as follows:Score= 3 * (X1 + X2 + …… + X6 ) + 2 * (X7 + Xs + …… + X12 ) + (X9 + X10(, +…… + X18 ). Based on BI-RADS,the positive predictive value of model cases was 1.5 %, 6.9 % ,22.1% ,62.5 % ,96.1 % followed by category 3,4A, 4B, 4C and 5, and it was 1.4%,3.4% ,21.1 % ,69.4% ,92.7% in test cases. Conclusions The scoring model could be useful for BI-RADS final assessment more obieetively,and could make it more convenient to predict the risk of breast cancer.

关 键 词:超声检查 乳腺疾病 乳腺影像报告与数据系统 

分 类 号:R445.1[医药卫生—影像医学与核医学] R737.9[医药卫生—诊断学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象