检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:曹传钊[1] 郑建涛[1] 徐海卫[1] 刘明义[1] 裴杰[1]
机构地区:[1]中国华能集团清洁能源技术研究院有限公司,北京102209
出 处:《节能技术》2015年第2期136-139,共4页Energy Conservation Technology
基 金:国家科技支撑计划(2011BAA04B03)
摘 要:为了对比研究某机组注水脱硝系统对燃机出力及热耗率等的影响,对某燃气轮机联合循环机组进行性能试验。试验共分3个试验工况:相同基础负荷注水前后性能试验及注水后机组最大出力工况,计算了不同工况下机组出力及热耗率,计算了注水脱硝系统投运后NOx减排量和增加的度电成本,最后分析了注水对机组运行的影响,试验结果表明注水能够提高燃气轮机出力,增加热耗,降低热效率,注水可以大幅降低燃气轮机NOx排放量。注水会增加度电成本,降低电厂经济性。In order to compare the performance of the gas turbine combined cycle unit before and after injecting water,the performance test was carried out for gas turbine combined cycle unit,and the experiment is performed on three testing working conditions: the test of performance under same basic load before and after water injection and unit maximum output working condition after water injection; calculate the unit output and thermal efficiency under different working conditions; the NOx emission reductions and increase the cost of per k Wh after water injection. At last,the effect of water injection to the unit operation is analyzed. The results showed that water injection can improve the gas turbine output,increase the heat consumption,and reduce thermal efficiency. Water can significantly reduce NOx emissions from gas turbines and will increase the cost of electricity as well as reduce power plant economy.
关 键 词:燃气轮机联合循环机组 注水 性能试验 热耗率 热效率 NOX排放量
分 类 号:TM611.24[电气工程—电力系统及自动化] TM611.3
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.16.40.244