配电变压器温升试验方法分析与比较  被引量:2

Analysis and Comparison of Methods for Distribution Transformer Temperature Rise Test

在线阅读下载全文

作  者:杨孝志[1] 叶飞[2] 王月兵[3] 

机构地区:[1]国网安徽省电力公司电力科学研究院,安徽合肥230022 [2]国网安徽省电力公司,安徽合肥230061 [3]国网安庆供电公司,安徽安庆246003

出  处:《江西电力职业技术学院学报》2015年第1期5-8,共4页Journal of Jiangxi Vocational and Technical College of Electricity

摘  要:温升指标是变压器一项非常重要的性能参数,实际工作中经常发现同一台变压器不同厂家检测结果存在明显差异。从试验方法角度介绍了3个典型厂家配电变压器温升指标测试方法,重点对变压器绕组断电时刻电阻值和油平均温升计算方法进行了较为详细的分析和比较,最后对变压器温升试验方法做了总结。Index of temperature rise is a very important performance parameters of transformer, there are obvious differences in test results of the same transformer from different manufactures often encountered in practice.The paper introduces the methods of temperature rise test for three typical transformer manufacturers only considering the different test method, focuses on the detailed analysis and comparison of the calculation method about winding resistance power-off time value and oil average temperature rise. Finally, some useful summaries of the transformer temperature rise test are also given.

关 键 词:温升试验 配电变压器 分析 比较 

分 类 号:TM406[电气工程—电器]

 