用于现场老化交联聚乙烯电力电缆的降解评估参数(英文)  被引量:7

A New Parameter for Degradation Assessment of Field Aged XLPE Power Cables

在线阅读下载全文

作  者:LIU Fei JIANG Pingkai LEI Qingquan ZHANG Li 

机构地区:[1]Shanghai Key Laboratory of Electrical Insulation and Thermal Aging, Department of Polymer Science and Engineering, Shanghai Jiao Tong University [2]Shanghai Electric Power Company

出  处:《高电压技术》2015年第4期1228-1236,共9页High Voltage Engineering

基  金:Project supported by Special Fund of the National Priority Basic Research of China(2014CB239503);National Natural Science Foundation of China(51277117);Shanghai Science and Technology Commission(11DZ2283000)

摘  要:The cables are more likely to deteriorate after several years of service in Shanghai,a city with a humid climate and abundant rainfall.Before assessing the aging status of those cables,it is critical to present effective test parameters which are sensitive to the aging process under special field conditions.Therefore,we have performed water tree investigation,tensile test,and differential scanning calorimetry(DSC)test on hundreds of cable samples removed from service.A large number of typical bowtie water trees were found in cable insulation and the water tree content was proposed to characterize the degree of water treeing.Based on Arrhenius Equation and equivalent thermal history parameters estimated from DSC profiles,we also proposed a new parameter ln(t/τθ)to characterize the aging status of cable insulation,Where,t is treated duration andτθis the thermal life under treated temperature.The applicabilities of water tree content,tensile strength,and ln(t/τθ)are tested using the analysis of variance(ANOVA).Then we investigated the relationship between the tensile strength and the water tree content using regression analysis,and analyzed the relationship between ln(t/τθ)and the tensile strength.The results indicated that each of these parameters performs differently with cables which experienced different degrees of age related degradation,and can be used to identify the aging status of field aged cables.The tensile strength can reflect the water treeing condition of field aged cables very well as a commonly used functional parameter.Since ln(t/τθ)is strongly related to the tensile strength,it is an effective parameter to characterize the aging status of field aged cable insulation.Using this newly proposed parameter is more time saving because of the convenience in sampling.The cables are more likely to deteriorate after several years of service in Shanghai, a city with a humid climate and abundant rainfall. Before assessing the aging status of those cables, it is critical to present effective test parameters which are sensitive to the aging process under special field conditions. Therefore, we have performed water tree investigation, tensile test, and differential scanning calorimetry(DSC) test on hundreds of cable samples removed from service. A large number of typical bowtie water trees were found in cable insulation and the water tree content was proposed to characterize the degree of water treeing. Based on Arrhenius Equation and equivalent thermal history parameters estimated from DSC profiles, we also proposed a new parameter ln(t/τθ) to characterize the aging status of cable insulation, Where, t is treated duration and τθ is the thermal life under treated temperature. The applicabilities of water tree content, tensile strength, and ln(t/τθ) are tested using the analysis of variance(ANOVA). Then we investigated the relationship between the tensile strength and the water tree content using regression analysis, and analyzed the relationship between ln(t/τθ) and the tensile strength. The results indicated that each of these parameters performs differently with cables which experienced different degrees of age related degradation, and can be used to identify the aging status of field aged cables. The tensile strength can reflect the water treeing condition of field aged cables very well as a commonly used functional parameter. Since ln(t/τθ) is strongly related to the tensile strength, it is an effective parameter to characterize the aging status of field aged cable insulation. Using this newly proposed parameter is more time saving because of the convenience in sampling.

关 键 词:交联聚乙烯电力电缆 评估 退化 老年人 电缆绝缘层 老化状态 DSC曲线 测试参数 

分 类 号:TM247[一般工业技术—材料科学与工程]

 