检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:周远华[1] 方海顺[1] 苏广海[1] 佟爱东[1] 李芷如 李薇[1]
机构地区:[1]广州市药品检验所,广州510160 [2]广东药学院,广州510006
出 处:《药物分析杂志》2015年第4期737-741,共5页Chinese Journal of Pharmaceutical Analysis
摘 要:目的:建立以腺苷为对照的高效液相色谱法测定三磷酸腺苷二钠注射液含量。方法:采用依利特Hypersil C8(4.6 mm×250 mm,5μm),柱温35℃,以0.05 mol·L-1磷酸盐缓冲液(含0.161%四丁基溴化铵,p H 7.0)为流动相,流速为1.0 m L·min-1,检测波长259 nm,以磷酸腺苷二钠和腺苷相对分子质量的理论比值2.062为系数、腺苷为对照外标法计算三磷酸腺苷二钠的含量。结果:腺苷质量浓度(C)在5.056~404.4 ng·m L-1范围时与峰面积(A)呈良好的线性关系,线性方程为A=3.219×104C+31.70,r=0.999 9;三磷酸腺苷二钠质量浓度(C)在9.939~795.1 ng·m L-1范围时与峰面积(A)呈良好的线性,线性方程为A=1.567×104C+22.16,r=1.000。腺苷和三磷酸腺苷二钠的定量限分别为7.6×10-5mg·m L-1和2.6×10-4mg·m L-1,重复性和中间精密度的RSD均为1.0%,三磷酸腺苷二钠回收率为101.1%(RSD=0.9%,n=9)。含量测定结果范围为94.2%~109.2%。结论:本实验建立的分析方法解决了未能获得含量确定且稳定的三磷酸腺苷对照的问题,提高了方法的专属性和定量准确性,可用于测定三磷酸腺苷二钠注射液的含量。Objective: To establish an HPLC method for determination of adenosine triphosphate disodium injection using adenosine as the reference. Methods: The method was established using the Elite Hypersil C8column( 4. 6 mm ×250 mm,5 μm) at the determination wavelength of 259 nm. The mobile phase was 0. 05 mol·L^-1phosphate buffer( with 0. 161% tetrabutylammonium bromide,p H 7. 0). The flow rate was 1. 0 m L·min- 1and the column temperature was 35 ℃. The content was calculated by HPLC- external standard method using the relative molecular mass ratio( 2. 062) of adenosine triphosphate disodium( ATP- 2Na) to adenosine as the coefficient and adenosine as the reference. Results: The adenosine calibration curve was linear over the concentration range of 5. 056-404. 4 ng·m L^-1( linear regression equation was A = 3. 219 × 104 C + 31. 70,r = 0. 999 9) and the ATP- 2Na calibration curve was linear over the concentration range of 9. 939- 795. 1 ng·m L^-1( linear regression equation was A = 1. 567 × 104 C + 22. 16,r = 1. 000). The limit of quantification was 7. 6 × 10- 5mg·m L^-1for adenosine and was2. 6 × 10- 4mg·m L^-1for ATP- 2Na. RSDs of both repeatability and intermediate precision were 1. 0%. The recovery of ATP- 2Na was 101. 1%( RSD = 0. 9%,n = 9). The contents were 94. 2%- 109. 2%. Conclusion: The proposed HPLC method solved the issue of obtaining the ATP- 2Na reference with accurate and stable content,improving the specificity and accuracy of the method,which can be successfully applied in determination of the content of adenosine triphosphate disodium injection.
关 键 词:腺苷 三磷酸腺苷二钠注射液 高效液相色谱法 校正系数 外标法
分 类 号:R917[医药卫生—药物分析学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.148.201.19