基于正交试验的立式混流泵启动参数优化配置  被引量:4

Optimizing Configuration of Vertical Mixed-Flow Pump Start-up Parameters Based on Orthogonal Test

在线阅读下载全文

作  者:林鹏[1] 梁兴[1,2] 刘梅清[1] 燕浩[1] 吴远为[1] 赵文胜[1] 刘志勇[1] 

机构地区:[1]武汉大学动力与机械学院,湖北武汉430072 [2]南昌工程学院机电学院,江西南昌330099

出  处:《华南理工大学学报(自然科学版)》2014年第12期97-103,共7页Journal of South China University of Technology(Natural Science Edition)

基  金:国家自然科学基金资助项目(51179135;51409197);湖北省水利重点科研项目(HBSLKJ201307)

摘  要:在具体分析立式混流泵结构特征和启动特点的基础上,以水泵启动过程最大水锤压力为控制目标,设计正交试验表,进行三维水锤计算并分析水泵电机启动时间、蝶阀开启时间和水泵叶片角度等因素对水泵启动过程的影响,为立式混流泵启动操作优化提供了有力的理论依据.研究结果表明:随着电机启动时间的增加,水泵最大启动水锤压力逐渐降低,最大降幅为4.4%;随着蝶阀开启时间增加,水泵最大启动水锤逐渐上升,最大增幅为3.4%;而随着叶片角度的增加,水泵最大启动水锤压力的变化比较复杂;电机启动时间对启动过程最大水锤压力的影响最为显著,而蝶阀开启时间对最大水锤的影响最弱.同时,考虑到水泵在部分叶片角度下的扬程曲线中明显存在马鞍区域,从保障水泵正常运行安全性的角度出发,水泵启动参数的最优配置为:电机启动时间26 s、蝶阀开启时间30 s和叶片角度-3°.Abstract: In the investigation, the structure features and start-up characteristics of vertical mixed-flow pumps are analyzed. Then, with the maximum water hammer pressure in the start-up process as the control target, an orthogo- nal test table is designed to calculate the 3-D water hammer and analyze the influences of the electric motor start-up time, the butterfly valve opening time and the blade angle on the pump start-up process, which provides a strong theoretical basis for the start-up operation optimization of the vertical mixed-flow pump. The results show that ( 1 ) as the electric motor start-up time increases, the maximum pressure of the pump start-up water hammer decreases gradually, with a maximum amplitude of 4.4% ; (2) as the butterfly valve opening time increases, the maximum pressure increases gradually, with a maximum amplitude of 3.4% ; ( 3 ) with the increase of the blade angle, the change of the maximum water pressure becomes more complicated ; and (4) the effect of the electric motor start-up time on the maximum water hammer pressure is the most significant while the effect of the butterfly valve opening time is the weakest. Besides, by taking into account the fact that there exist saddle regions in the head curves at certain blade angles and from the perspective of guaranteeing the normal running of water pump, the optimal start- up parameters are found to be an electric motor start-up time of 26 s, a butterfly valve open time of 30 s and a blade angle of -3°.

关 键 词:立式混流泵 正交试验 水力过渡过程 启动参数 优化配置 CFD 

分 类 号:TH313[机械工程—机械制造及自动化]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象