作 者:杨祥[1]
机构地区:[1]苏州西门子电器有限公司,江苏苏州215129
出 处:《电器与能效管理技术》2015年第8期26-29,共4页Electrical & Energy Management Technology
摘 要:通过对低压电器通断能力试验的分析,从试验电路设置的角度对影响通断能力试验恢复电压的几个电路特性参数进行相应的调节设置,使其在满足标准规定的要求基础上,调试出试验所需的恢复电压,满足试验要求。通过理论与实例的分析与判断,对试验电路设置过程中影响恢复电压的几个比较常见的认识盲区进行了阐述与分析,可为检测试验站进行线路调节设置与结果判断提供参考。Based on the meaning analysis of low voltage apparatus' s making breaking capability test,some electric circuit test parameters which influence the test recovery voltage were set up from the angle of electric circuit adjusting to adjust the required recovery voltage objectively,and to meet the requirements of test standard.Some normal recognition blind zones regarding the factors of influencing the test recovery voltage were clarified and analyzed based on the theory analysis and practical judgment,which could be used as a good reference to the local and aboard test station in the area of electric circuit setup and test result judgment.