摘  要:由于炼钢转炉生产工艺的复杂性,转炉的烟尘特性呈周期性变化,静电除尘器的收尘效率也不同。本文建立了热态的静电除尘器实验台,并从某炼钢厂取样转炉烟尘,实验研究了静电除尘器对转炉烟尘的收尘效率,测试了A型与B型两种极板的极板间距、放电电压对效率的影响,研究结果对于转炉干法静电除尘器的设计具有指导意义。Due to complexity of CF production process, dust characteristic of CF reflects periodical change and dust collecting efficiency of Electrostatic collector is different. Thermal electrostatic collector test table is established, CF dust is taken as sample in a steel plant, dust collecting efficiency of CF dust can be researched in the test, polar plate spacing of Type A polar plate and Type B polar plate and the effect of discharge voltage on efficiency will be tested, research result has an important guiding significance for design of CF dry electrostatic dust collector.