机构地区:[1]中国建筑科学研究院,北京100013 [2]北京科技大学,北京100083
出 处:《建筑科学》2015年第4期40-44,共5页Building Science
基 金:"十二五"国家科技支撑计划项目"建筑室内颗粒物污染及其复合污染控制关键技术研究"(2012BAJ02B02)
摘 要:根据公共建筑室内PM2.5污染来源、运动规律,结合室内PM2.5污染控制通风过滤模型,分析了通风换气对降低室内PM2.5污染浓度的影响,给出了空气过滤器过滤效率计算公式及简化选型计算公式,提供了室内PM2.5浓度控制标准要求,结合目前常见的集中空调系统空气过滤器配置工况,通过实例计算,给出了集中空调系统空气过滤器等级组合建议。Based on the source ofindoor and outdoor PM2.5 pollution in public buildings and its law of motion as well as the ventilation and filtering model for indoor PM2.5 pollution control, the influence of ventilation and air change on the decrease of indoor PM2.5 concentration was analyzed, the calculation formula of efficiency of air filter and the calculation formula for simplification and model selection were provided, and the criteria for indoor PM2.5 concentration control was prepared. By referring to common working condition of air filter of central air-conditioning system, the combination of grade of air filter of central air-conditioning system was recommended in an example.
关 键 词:公共建筑 通风 空气过滤 PM2.5污染 过滤效率
分 类 号:TU834.8[建筑科学—供热、供燃气、通风及空调工程]