Ceramic on Ceramic or Ceramic-on-polyethylene for Total Hip Arthroplasty: A Systemic Review and Meta-analysis of Prospective Randomized Studies  被引量:5

Ceramic on Ceramic or Ceramic-on-polyethylene for Total Hip Arthroplasty: A Systemic Review and Meta-analysis of Prospective Randomized Studies

在线阅读下载全文

作  者:Yu-Lei Dong Tao Li Ke Xiao Yan-Yan Bian Xi-Sheng Weng 

机构地区:[1]Department of Orthopaedic Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing 100730, China

出  处:《Chinese Medical Journal》2015年第9期1223-1231,共9页中华医学杂志(英文版)

摘  要:Background:Wear debris of polyethylene has become a restraining factor of the durability for total hip arthroplasty (THA).Ceramic on ceramic (COC) has better wear resistance while the squeaking sound and prosthesis fracture are of concern.It is still a controversy that bearing couples are better for THA.Methods:We performed a systematic review of all English articles identified from PubMed (1966-),Embase (1980-) and the Cochrane Library.Clinical outcomes,complications,revision rates,and radiographic outcomes of COC-THA and ceramic on polyethylene (COP)-THA were compared and evaluated.Results:Eight prospective randomized trials enrolling a total of 1508 patients and 1702 THA surgeries were identified.Our results demonstrated the prosthesis fracture and the squeaking sound is significantly higher in COC group and higher wear rate of the COP.Hip function,loosening rate,dislocation rate,revision rate,and the osteolysis rate were comparable between two groups.According to Grading of Recommendations Assessment,Development and Evaluation system assessment,the strength of evidence was high for prosthesis fracture,dislocation,osteolysis,and moderate for radiolucent line or loosening,hip noise,and revision.Conclusions:Up to now,there is insufficient evidence to identify any clinical advantage of COC compared with COP.Longer follow-up of larger randomized trial is needed to clarify the outcomes.Background:Wear debris of polyethylene has become a restraining factor of the durability for total hip arthroplasty (THA).Ceramic on ceramic (COC) has better wear resistance while the squeaking sound and prosthesis fracture are of concern.It is still a controversy that bearing couples are better for THA.Methods:We performed a systematic review of all English articles identified from PubMed (1966-),Embase (1980-) and the Cochrane Library.Clinical outcomes,complications,revision rates,and radiographic outcomes of COC-THA and ceramic on polyethylene (COP)-THA were compared and evaluated.Results:Eight prospective randomized trials enrolling a total of 1508 patients and 1702 THA surgeries were identified.Our results demonstrated the prosthesis fracture and the squeaking sound is significantly higher in COC group and higher wear rate of the COP.Hip function,loosening rate,dislocation rate,revision rate,and the osteolysis rate were comparable between two groups.According to Grading of Recommendations Assessment,Development and Evaluation system assessment,the strength of evidence was high for prosthesis fracture,dislocation,osteolysis,and moderate for radiolucent line or loosening,hip noise,and revision.Conclusions:Up to now,there is insufficient evidence to identify any clinical advantage of COC compared with COP.Longer follow-up of larger randomized trial is needed to clarify the outcomes.

关 键 词:CERAMIC-ON-CERAMIC META-ANALYSIS Randomized Studies Total Hip Arthroplasty 

分 类 号:Q141[生物学—生态学] O211[生物学—普通生物学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象